1 Megawat Natural Gas Generator

● Fuel gas: natural gas, biogas, biomass gas ● Clean energy and friendly to the environment ● Low procurement and running costs; ● Easy maintenance and easy access to spares ● Fast maintenance and overhaul service ● Different options to meet your requirements: 1. Soundproof system 2. Heat recovery

Products Details

Function Introduction

01 Unit Features The natural gas generator set is suitable for operation in a range of multiple environmental conditions, and its economic performance is better than that of the existing diesel engine; The unit can quickly respond to load changes and deal with more complex conditions. The gas generator unit (standby generator for natural gas) adopts the integrated partition box design, the box can meet the operation of multiple environmental conditions, and has the functions of rain proof, sand dust proof, mosquito proof, noise reduction, etc. The box body is designed and produced with special structure and materials of high strength container. l The shape of gas generator box meets the national transportation standard. 02 Unit Composition And Partition 发电机主图03
Gas powered generator

Power Generation Efficiency

(take 250KW as an example for the following data) • The full load gas consumption of the generator set is 70-80nm ³/ h • The power of generating set is 250kw/h • 1 kW/h=3.6MJ • 1 Nm³/H natural gas calorific value 36MJ • 31.25% ≤ Power generation efficiency ≤ 35.71% • 1Nm ³ The natural gas power generation is 3.1-3.5kw/h

Adaptability Of Gas Medium

• Applicable gas source calorific value range: 20MJ/Nm³-45MJ/Nm³ • Applicable gas source pressure range: low pressure (3-15kpa), medium pressure (200-450kpa), high pressure (450-700kpa); • Suitable gas source temperature range: -30 ℃ to 50 ℃; • Design and calibrate the optimal system scheme and control strategy according to the customer’s gas conditions to obtain the optimal gas source economy and equipment stability.

Product models

Genset

Model

Fuel type

Natural gas

Natural gas

Natural gas

Natural gas

Natural gas

Genset Model

RTF250C-41N

RTF300C-41N

RTF500C-42N

RTF750C-43N

RTF1000C-44N

Rated power

kw

250

300

500

750

1000

kVA

312.5

375

625

937.5

1250

Reserve power

kw

275

330

550

825

1100

kVA

343.75

412.5

687.5

1031.25

1375

Gas consumption

3.2NkW/Nm³

3.5NkW/Nm³

3.2NkW/Nm³

3.2NkW/Nm³

3.2NkW/Nm³

Engine

Engine Model

1-T12

MANE 2676

2-T12

3-T12

4-T12

Number of cylinders * engineering * stroke (mm)

6-126X155

6-126X166

6-126X155

6-126X155

6-126X155

Engine displacement (L)

2*11.596

12.42

2*11.596

3*11.596

4*11.596

Starting Method

24VDC Electric Start

Intake Method

Booster intercooler

Fuel Control

Closed loop control of oxygen sensor

ignition Control

Electronic control single cylinder independent ignition

Speed control

Electronic speed regulation

Rated Speed

1500或1800

Cooling Method

Closed-Loop water cooling

Generator

Rated Voltage (V)

230/400

230/400

230/400

230/400

230/400

Rated Current(A)

451

541.2

902

1353

1804

Rated Frequency (Hz)

50or60

50or60

50or60

50or60

50or60

Supply Connection

3 Phases 4  Lines

Rated Power Factor

0.8 Delay l

0.8 Delay l

0.8 Delay l

0.8 Delay l

0.8(Delay l

Dimension

Net weight (kg)

3200

3600

9800

15200

18600

External Dimensions(L*W*H)mm

4200X1500X2450

4200X1500X2450

6400X3000X3000

10600X3000X3000

10600X3000X3000

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours